Manufacturer direct · OEM & ODMopheliamyers221@gmail.com
KESAESTHETIC EQUIPMENT
MED-360 Multi Multifunction Body Contouring and Skin Care Machine

Product presentation · Confirm configuration with your quotation

KES / Body contouring

MED-360 Multi Body Contouring Machine Manufacturer

MED-360 Multi is a multifunction body contouring and skin care platform with four standard handpieces and an optional cavitation handpiece. Examine the RF, vacuum and rolling specifications, then define the equipment package you want quoted.

View specifications ↓
For distributors and professional procurement.
Share your destination market when you enquire.
Know your configuration

Technical specifications

MED-360 Multi · Published configuration
Model NO.MED-360 Multi
RF Frequency10MHzDeep-RF
Radio Frequency PowerUp to 200W
DeliveryTypePulse;CW
Vacuum Pressure0~70KPa
LED Light690nm(LED),700mA
Rolling Way4;In,OutForward,Backward
Handpiece4 Handpieces Standard(I&lI&IlI&IV)
Handpiece1*Handpiecel(Large Body Area);1*Handpiecell (Small Body Area)
Handpiece1*Handpiecelll(Face);1*HandpiecelV(Eyelid)
HandpieceOPTIONAL:20~80KHz Cavitation Handpiece
CoolingAir Cooling
Continuous Working18 Hours everyday
Electrical Requirements220V/110V±10%50/60Hz
Net Weight50KG
Dimensions(WxLxH)640mmx410mmx1100mm

Options and order-specific details should be confirmed in the final quotation.

01

Start with the four-handpiece configuration

MED-360 Multi brings several equipment functions into a multifunction platform. Its published specification lists four standard handpieces, identified as I, II, III and IV. For purchasing purposes, those four components are a more useful starting point than a broad multifunction label. They give your team a concrete list to check against the proposed quotation, packing information and eventual equipment handover.

The handpiece descriptions distinguish large body area, small body area, face and eyelid entries. These are the source's component labels, not an instruction to use the machine on an individual or a guarantee that every proposed use is authorized in your market. Ask for the current instructions and the precise identification of each supplied component when evaluating the package.

Include the word Multi in correspondence. This product should be quoted and documented under its complete MED-360 Multi identity. If your shortlist contains another platform with a similar model name, keep separate records rather than combining their accessories or technical figures. A well-defined starting configuration makes it easier to discuss which functions your organization needs and which details require confirmation before purchase.

At the equipment-review stage, request a visual identification of the supplied handpiece types alongside their written names. Your receiving team can then compare the delivered components with the agreed package without guessing which item a broad description refers to. Ask which identifiers should be used in later support correspondence and whether any accompanying holders or cables are separate line items. This does not establish additional included equipment; it is a way to make the proposed package explicit. Resolve these details while the quotation is still being discussed, especially if the optional handpiece is also under consideration.

02

Treat cavitation as an option

The cavitation handpiece is listed as optional, with a published frequency entry of 20–80kHz. It is not part of the four-handpiece standard count. If it is important to your equipment brief, state that requirement directly and ask whether it is included in the proposed offer, separately priced or subject to a different configuration arrangement.

Ask how an optional handpiece is identified in the equipment schedule and what documentation accompanies it. Do not infer that an option can be retrofitted later, transferred between machines or used with any unit sharing the same model family. Those are compatibility questions for the actual configuration, and the answer should remain attached to the quotation you approve.

A distributor preparing a catalog should make the same distinction in customer-facing descriptions. List the base package separately from options so downstream buyers can understand what a price includes. For a facility evaluating a single machine, decide whether the option is required for the purchase decision or simply worth discussing. That distinction keeps the quotation focused and avoids approving an accessory bundle that does not match your original requirements.

03

RF and vacuum specifications in context

The published RF frequency is 10MHz, and radio-frequency power is listed as up to 200W. The delivery-type entry lists Pulse and CW. These specifications identify aspects of the equipment configuration; they do not establish clinical performance, a recommended setting or the superiority of one operating mode for an individual. Ask for the current operating documents that explain the controls and their limits.

Vacuum pressure is listed as 0–70kPa. Keep that pressure figure separate from the RF power entry when making a technical comparison. They describe different properties and should not be collapsed into a single measure of machine strength. If your team needs to understand how the available settings are presented or combined, request clarification for the actual handpieces being supplied.

A useful technical review can ask which settings are available for each handpiece, how those settings are identified on the interface and what checks precede operation. This is an equipment review, not an invitation to design treatment protocols from a website. Request any missing information rather than assuming that a setting available on one attachment is available on every attachment in the package.

04

Rolling controls, light and everyday handling questions

The rolling entry lists four directions: inward, outward, forward and backward. The LED entry lists 690nm and 700mA. These details help distinguish MED-360 Multi's documented configuration, but they should remain attached to their respective specification labels. A light wavelength does not by itself establish an outcome, and a direction list does not describe the complete operating procedure.

When asking for a demonstration, focus on the equipment questions that affect your purchase. How are handpieces selected? How are their settings displayed? What does the operator need to check when changing components? Ask for the relevant instructions and an explanation of the supplied configuration, without treating a sales demonstration as a replacement for professional training or local authorization.

The equipment lists air cooling. Request the installation and maintenance information needed to plan its position, ventilation and cleaning arrangements. Do not guess the required clearance from a photograph. Ask which consumables, cleaning materials or service items are specified for the machine, and which of those are included in the order. Keeping these questions alongside the handpiece list helps you assess the practical package beyond the cabinet itself.

05

Space, electrical supply and delivery planning

The listed dimensions are 640 × 410 × 1100mm in width, length and height, and the net weight is 50kg. Those are machine figures. Request the separate packed dimensions and gross weight if you need to plan freight, a loading route or access through a building. A shipping quotation should make clear whether it covers only transport or also any unloading and positioning work.

Electrical requirements are listed as 220V or 110V, with a ±10% entry and 50/60Hz. Confirm the supply configuration for the ordered unit and the applicable installation requirements. Ask a qualified person to assess the proposed location rather than assuming that a plug adapter is the only preparation needed. Record the voltage requirement in the equipment schedule to keep it visible through ordering.

The table also includes an eighteen-hour daily continuous-working entry. Treat that as a published equipment entry whose operating conditions need clarification. It is not a guarantee of appointment throughput, uninterrupted treatment operation or freedom from maintenance. Ask about the applicable duty conditions and care instructions before making staffing or scheduling assumptions around the platform.

06

Compare a multifunction purchase with your actual requirements

A multifunction machine is worth evaluating as a complete equipment package. List the functions your business intends to offer or distribute, then connect each requirement with a specified handpiece and the documentation needed to assess it. If your team cannot identify which included component answers a requirement, make that a quotation question rather than filling the gap with a general marketing label.

For a distributor, ask how individual handpieces, cables and related components would be identified for replacement orders. For a facility, consider how the machine's documents and accessory records will be retained by the people responsible for equipment management. Clarify whether any recommended spare or maintenance item is part of the initial offer or a separate purchase. None should be assumed from a photograph alone.

If you want to explore private-label equipment, start from the agreed four-handpiece package and identify the optional cavitation requirement separately. Then describe the branding, interface or packaging changes you would like evaluated. Ask which changes are feasible, how they would be approved and whether they affect quantities, cost or timing. A branding request should not silently change the technical scope of the machine being compared.

07

Turn the shortlist into an order discussion

Send an inquiry that names MED-360 Multi, your destination country, expected quantity and the required handpiece configuration. Explain whether you are comparing equipment for your own professional facility or building a distributor range. Add the unresolved questions that would change your decision, such as an optional handpiece requirement, a documentation request or a site-preparation concern.

Ask for model-specific records relevant to your intended market and have them assessed where required. The equipment's presence in a body contouring category does not establish approval for every application or operator. This page does not promise weight loss, a particular measurement change or any individual result. Keep purchasing evaluation and professional clinical decisions in their appropriate contexts.

Finally, request the support and commercial details in writing. Clarify training arrangements, installation responsibilities, warranty coverage, replacement-component ordering and delivery scope. Distinguish production readiness from dispatch and transportation estimates. Once those items are confirmed, your team can compare a defined equipment package instead of a collection of features without a clear order boundary.

Before you enquire

Questions, answered.

How many handpieces are standard on MED-360 Multi?

The published package lists four standard handpieces, identified as I through IV. Ask for the current itemized equipment schedule and confirm the description of each component. The optional cavitation handpiece should be shown separately if it is requested.

Is cavitation included in every quotation?

No inclusion should be assumed. Cavitation is listed as optional. Name it in your inquiry and ask whether the offered configuration includes the relevant handpiece, what documentation applies and how it is identified in the quoted package.

What do the RF figures tell a procurement team?

The published entries identify 10MHz RF frequency and up to 200W RF power. They help describe the machine but do not establish a treatment protocol or guarantee an outcome. Review the full configuration and current instructions rather than selecting equipment by one number.

Can I use the net dimensions to book freight?

Ask for packed dimensions and gross weight before booking transport. The listed 640 × 410 × 1100mm dimensions and 50kg net weight describe the machine, not necessarily its shipping package or any additional accessories.

What should I confirm about support before ordering?

Request the training and installation arrangements available for your location, the written warranty scope and the process for ordering replacement components. Ask who is responsible for transport, technical work and any associated charges; this page does not establish a universal service package.

Keep exploring

In the same collection.

Explore category →
Your next equipment project

Let’s build your shortlist.

Tell us your market, preferred model and configuration questions.

Discuss your requirementsChat on WhatsApp ↗
WhatsApp ↗